Skip to content

Features, Dimensions & Installation ​

1.1 Key Features ​

  • Wide DC Input Voltage: 5V – 40V / 75V depending on model (check the enclosure nameplate for exact voltage and motor power ratings).
  • Comprehensive Protection: Built-in reverse-polarity protection and surge/absorption circuits for reliable operation.
  • 6 Operating Modes: Easily switchable via the mode button with video guides available.
  • Dual Limit Switches: Supports independent forward and reverse limit switches.
  • Flexible Sensor Support: Normally-open (NO) active-low trigger — supports mechanical switches, proximity sensors, and 3-wire NPN-NO sensors (PNP supported via factory circuit customization upon order).
  • C45 DIN-Rail Mounting: Standard 35mm DIN-rail mount for quick installation; supports 1-to-1 or 1-to-many control.
  • Wireless & Smart Extensions: Optional RF remote control, WiFi remote/scheduled control, and Bluetooth Mini Program control.
  • Adjustable Overcurrent Protection: Models with overcurrent protection allow customizing the current trip threshold.
  • Proven Reliability: Mass-deployed in R&D, industrial automation, medical devices, automotive retrofits, and electronics.

1.2 Enclosure Dimensions ​

ModelsDimensions (L × W × H)Enclosure Reference
MR2, MR5, MS284 × 54 × 32 mm (credit-card footprint)MR2/MR5/MS2 Enclosure
MR3, MR6, MS6, ME390 × 71 × 40 mm (high-power enclosure)MR3/MR6/MS6/ME3 Enclosure

Note

Minor tolerances may exist in manual measurement; refer to the actual unit. Detailed CAD/PDF mechanical drawings for PCB mounting holes are available on request.


1.3 Installation & Pre-Power Checklist ​

Environment ​

  • Ambient Temperature: -10°C to 80°C (ensure good ventilation if operating above 60°C continuously).
  • Location: Free of corrosive/flammable gases or liquids, mounted firmly away from heavy vibration.

Before Powering On ​

  1. Check the nameplate on the enclosure to confirm supply voltage and motor power rating.
  2. Power wiring: Observe DC + / – polarity. The indicator lights up when powered correctly (if reversed, reverse-polarity protection prevents damage and the LED stays off).
  3. Motor wiring: Motor leads are non-polarized — swap the two motor wires if rotation direction is reversed. Never connect DC power to the motor terminals.