Features, Dimensions & Installation
1.1 Key Features
- Wide DC Input Voltage:
5V – 40V/75Vdepending on model (check the enclosure nameplate for exact voltage and motor power ratings). - Comprehensive Protection: Built-in reverse-polarity protection and surge/absorption circuits for reliable operation.
- 6 Operating Modes: Easily switchable via the mode button with video guides available.
- Dual Limit Switches: Supports independent forward and reverse limit switches.
- Flexible Sensor Support: Normally-open (NO) active-low trigger — supports mechanical switches, proximity sensors, and 3-wire NPN-NO sensors (PNP supported via factory circuit customization upon order).
- C45 DIN-Rail Mounting: Standard
35mmDIN-rail mount for quick installation; supports 1-to-1 or 1-to-many control. - Wireless & Smart Extensions: Optional RF remote control, WiFi remote/scheduled control, and Bluetooth Mini Program control.
- Adjustable Overcurrent Protection: Models with overcurrent protection allow customizing the current trip threshold.
- Proven Reliability: Mass-deployed in R&D, industrial automation, medical devices, automotive retrofits, and electronics.
1.2 Enclosure Dimensions
| Models | Dimensions (L × W × H) | Enclosure Reference |
|---|---|---|
| MR2, MR5, MS2 | 84 × 54 × 32 mm (credit-card footprint) | ![]() |
| MR3, MR6, MS6, ME3 | 90 × 71 × 40 mm (high-power enclosure) | ![]() |
Note
Minor tolerances may exist in manual measurement; refer to the actual unit. Detailed CAD/PDF mechanical drawings for PCB mounting holes are available on request.
1.3 Installation & Pre-Power Checklist
Environment
- Ambient Temperature:
-10°C to 80°C(ensure good ventilation if operating above60°Ccontinuously). - Location: Free of corrosive/flammable gases or liquids, mounted firmly away from heavy vibration.
Before Powering On
- Check the nameplate on the enclosure to confirm supply voltage and motor power rating.
- Power wiring: Observe DC
+/–polarity. The indicator lights up when powered correctly (if reversed, reverse-polarity protection prevents damage and the LED stays off). - Motor wiring: Motor leads are non-polarized — swap the two motor wires if rotation direction is reversed. Never connect DC power to the motor terminals.