Modes & Overcurrent Protection
Both MODE and IS / I-SET share the red RFD indicator LED. All settings are stored in internal EEPROM and retained across power cycles.
1. Operating Mode (MODE Button)
To prevent accidental changes, the controller powers up in a mode-locked state. Unlock before switching:
How to Switch Modes
- Press
MODE5 times consecutively (LED flashes once per tap) and release for0.8s:- The red LED blinks 3 times, resetting to Self-Lock and opening a 6-second change window.
- Within 6 seconds, press
MODE1–4 times and release for0.8s:- The red LED blinks 2 times, saving the new mode and locking again immediately.
| Presses | Mode | Behavior |
|---|---|---|
| 1 | Self-Lock (Default) | Tap to start continuous run; tap same direction to stop, or opposite direction to stop and reverse; stops automatically at limit |
| 2 | Inching (Jog) | Runs only while K1/K2 or app button is held; stops immediately on release |
| 3 | Infinite Loop | Runs continuously between LS1 and LS2 limits until manually stopped |
| 4 | Single Cycle | Completes one full round-trip (two limit triggers) and stops automatically |
Emergency Stop
In any mode, pressing K1 + K2 simultaneously (or tapping Stop in the Mini Program) stops the motor immediately. Both keys must be released before resuming.
2. Overcurrent Protection (IS / I-SET Button)
- Range:
1A – 10A(number of taps = amperes; default5A, saved in EEPROM). - How to Set:
- Press
I-SETNtimes consecutively (N = 1 ~ 10, e.g. 3 taps for3A). The LED flashes once per tap. - Release for
0.8s. After a brief200mspause, the red LED blinksNtimes to confirm the saved threshold. - More than 10 taps are ignored to prevent accidental misconfiguration.
- Press
Trip & Recovery Behavior
- Startup Inrush Blanking: Ignores motor startup surge current for the first
500msafter each start. - Overcurrent Trip: If current exceeds the threshold continuously for ~
50ms, the relays cut off immediately and theRFDred LED stays solid ON. - Recovery: Clear any mechanical jam or overload, then restart the motor (release button first in Inching mode) or press a setup key to clear the fault LED.