Hardware & Wiring ​

1. Power & Motor Terminals ​

TerminalDescriptionNotes
Power Input (P1)DC supply (VIN+ / GND)Match your motor's rated voltage and observe polarity. Size input fuse F1 to your load current.
Motor Output (P2)M+ / M- to DC brushed motorDual relays reverse polarity for FWD/REV. Swap M+ and M- if direction is inverted.

2. External Buttons & Limit Switches (P4) ​

4 opto-isolated inputs (active low / triggered):

PinFunctionBehavior
KG1 (K1)External ForwardTriggers forward run; pressing KG1 + KG2 together triggers emergency stop
KG2 (K2)External ReverseTriggers reverse run; pressing KG1 + KG2 together triggers emergency stop
LS1Forward Limit SwitchImmediately stops forward motion (highest priority in all modes)
LS2Reverse Limit SwitchImmediately stops reverse motion (highest priority in all modes)

Sensor Wiring (NPN vs PNP)

  • NPN sensors pull to 0V when active: connect COM to supply positive (e.g. 24V).
  • PNP sensors output positive voltage when active: connect COM to GND.
  • Limit switches always have highest priority. When LS1 is active, forward motion is blocked while reverse motion remains available to back off the limit.

3. On-Board Buttons & LEDs ​

SilkscreenNameFunction
CLR4G Pair / Reset ButtonShort-press once: pair with Mini Program; Hold 5s: clear all bindings
MODEMode ButtonSelect Self-Lock / Inching / Loop / Single-Cycle (shares RFD LED)
IS (I-SET)Overcurrent ButtonPress 1–10 times to set 1A–10A threshold (shares RFD LED)
PWR (Green)Power LEDSolid ON when powered
NET (Red)4G Network LEDSlow blink: connecting; Solid ON: online; Fast blink: pair / reset feedback
RFD (Red)Mode / Overcurrent LEDBlinks for button confirmation; Solid ON when overcurrent protection trips
FWD (Green)Forward Relay LEDLit during forward rotation
REV (Red)Reverse Relay LEDLit during reverse rotation