Hardware & Wiring
1. Power & Motor Terminals
| Terminal | Description | Notes |
|---|---|---|
Power Input (P1) | DC supply (VIN+ / GND) | Match your motor's rated voltage and observe polarity. Size input fuse F1 to your load current. |
Motor Output (P2) | M+ / M- to DC brushed motor | Dual relays reverse polarity for FWD/REV. Swap M+ and M- if direction is inverted. |
2. External Buttons & Limit Switches (P4)
4 opto-isolated inputs (active low / triggered):
| Pin | Function | Behavior |
|---|---|---|
KG1 (K1) | External Forward | Triggers forward run; pressing KG1 + KG2 together triggers emergency stop |
KG2 (K2) | External Reverse | Triggers reverse run; pressing KG1 + KG2 together triggers emergency stop |
LS1 | Forward Limit Switch | Immediately stops forward motion (highest priority in all modes) |
LS2 | Reverse Limit Switch | Immediately stops reverse motion (highest priority in all modes) |
Sensor Wiring (NPN vs PNP)
- NPN sensors pull to
0Vwhen active: connectCOMto supply positive (e.g.24V). - PNP sensors output positive voltage when active: connect
COMtoGND. - Limit switches always have highest priority. When
LS1is active, forward motion is blocked while reverse motion remains available to back off the limit.
3. On-Board Buttons & LEDs
| Silkscreen | Name | Function |
|---|---|---|
CLR | 4G Pair / Reset Button | Short-press once: pair with Mini Program; Hold 5s: clear all bindings |
MODE | Mode Button | Select Self-Lock / Inching / Loop / Single-Cycle (shares RFD LED) |
IS (I-SET) | Overcurrent Button | Press 1–10 times to set 1A–10A threshold (shares RFD LED) |
PWR (Green) | Power LED | Solid ON when powered |
NET (Red) | 4G Network LED | Slow blink: connecting; Solid ON: online; Fast blink: pair / reset feedback |
RFD (Red) | Mode / Overcurrent LED | Blinks for button confirmation; Solid ON when overcurrent protection trips |
FWD (Green) | Forward Relay LED | Lit during forward rotation |
REV (Red) | Reverse Relay LED | Lit during reverse rotation |